11 Test Run and Program Run

242

Resuming program run with the START button
You can resume program run by pressing the machine START
button if the program was interrupted in one of the following ways:

The machine STOP button was pressed

A programmed interruption

The EMERGENCY STOP button was pressed (machine-dependent
function)

If you interrupted program run with the INTERNAL STOP
soft key, you can select another block with the GOTO key
and resume machining there.

If you select the BEGIN PGM block (block 0), the TNC
resets all stored data (tool data, etc.)

If you interrupted program run during a program section
repeat, you can only use GOTO to select other blocks
within the program section repeat.

Resuming program run after an error

If the error message

is not blinking

ú

Remove the cause of the error.

ú

To clear the error message from the screen, press the CE key.

ú

Restart the program, or resume program run at the place at which
it was interrupted.

If the error message

is blinking

ú

Press and hold the END key for two seconds. This induces a TNC
system restart.

ú

Remove the cause of the error.

ú

Start again.

If you cannot correct the error, write down the error message and
contact your repair service agency.