297

HEIDENHAIN TNC 410

15.4

TNC Er

ro

r Messag

es

Wrong RPM

Program a spindle speed within the programmed range.

Chamfer not permitted

A chamfer block must be located between two straight-line blocks with
identical radius compensation.

Faulty program data

The program that was read in through the data interface contains
incorrect block formats.

No editing of running program

A program cannot be edited while it is being transmitted or executed.

Circle end pos. incorrect

Enter complete information for connecting arc.

Enter end points that lie on the circular path.

Circle center undefined

Define a circle center with the CC key.

Define a pole with the CC key.

Label number not found

Only call label numbers that have been set.

Scaling factor not permitted

Enter identical scaling factors for coordinate axes in the plane of the
circle.

PGM section cannot be shown

Enter a smaller tool radius.

4-D movements cannot be graphically simulated.

Enter a tool axis for simulation that is the same as the axis in the BLK

FORM.

Radius comp. undefined

Enter radius compensation RR or RL in the first subprogram for
Cycle 14 CONTOUR GEOMETRY.

Rounding-off undefined

Enter tangentially connecting arcs and rounding arcs correctly.

Rounding radius too large

Rounding arcs must fit between contour elements.

Key non-functional

This message always appears when you press a key that is not needed
for the current dialog.

Stylus already in contact

Before probing, pre-position the stylus where it is not touching the
workpiece surface.

Advertising