HEIDENHAIN TNC 620 (81760x-02) ISO programming User Manual

Page 340

Advertising
background image

Programming: Q parameters

9.11

Preassigned Q parameters

9

340

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

Measurement results from touch probe cycles (see
also User’s Manual for Cycle Programming)

Measured actual values

Parameter value

Angle of a straight line

Q150

Center in reference axis

Q151

Center in minor axis

Q152

Diameter

Q153

Pocket length

Q154

Pocket width

Q155

Length of the axis selected in the cycle

Q156

Position of the centerline

Q157

Angle in the A axis

Q158

Angle in the B axis

Q159

Coordinate of the axis selected in the

cycle

Q160

Measured deviation

Parameter value

Center in reference axis

Q161

Center in minor axis

Q162

Diameter

Q163

Pocket length

Q164

Pocket width

Q165

Measured length

Q166

Position of the centerline

Q167

Determined space angle

Parameter value

Rotation about the A axis

Q170

Rotation about the B axis

Q171

Rotation about the C axis

Q172

Workpiece status

Parameter value

Good

Q180

Rework

Q181

Scrap

Q182