Test run and program run

16.2 Showing the workpiece blank in the working space (option 20)

16

512

TNC 620 | User's ManualDIN/ISO Programming | 2/2015

16.2

Showing the workpiece blank in the
working space (option 20)

Application

In the

Test Run operating mode, you can graphically check the

position of the workpiece blank or reference point in the machine’s
working space and activate work space monitoring in the

Test Run

mode: Press the

BLANK IN WORK SPACE soft key to activate this

function. You can use the soft key

SW LIMIT MONITORING (2nd

soft-key row) to activate or deactivate the function.
A transparent cuboid represents the workpiece blank. Its
dimensions are shown in the

BLK FORM table. The TNC takes the

dimensions from the workpiece blank definition of the selected

program. The workpiece cuboid defines the coordinate system. Its

datum lies within the traverse-range cuboid.
For a test run it normally does not matter where the workpiece

blank is located within the working space. However, if you activate

working-space monitoring, you must graphically shift the workpiece

blank so that it lies within the working space. Use the soft keys

shown in the table.
You can also activate the current datum for the

Test Run operating

mode (see the following table).

Soft keys

Function

Shift workpiece blank in positive/negative X

direction

Shift workpiece blank in positive/negative Y

direction

Shift workpiece blank in positive/negative Z

direction

Show workpiece blank referenced to the

set datum

Switch monitoring function on or off

Note that even with

BLK FORM CYLINDER, a cuboid

is shown in the working space as workpiece blank.
When

BLK FORM ROTATION is used, no workpiece

blank is shown in the working space.