DATUM FROM OUTSIDE OF CORNER (Cycle 414, DIN/ISO: G414) 15.8

15

TNC 640 | User's Manual Cycle Programming | 1/2015

499

Cycle parameters

1st meas. point 1st axis Q263 (absolute):
Coordinate of the first touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999
1st meas. point 2nd axis Q264 (absolute):
Coordinate of the first touch point in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999
Spacing in 1st axis Q326 (incremental): Distance
between the first and second measuring points in
the reference axis of the working plane. Input range
0 to 99999.9999
3rd meas. point 1st axis Q296 (absolute):
Coordinate of the third touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999
3rd meas. point 2nd axis Q297 (absolute):
Coordinate of the third touch point in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999
Spacing in 2nd axis Q327 (incremental): Distance
between third and fourth measuring points in the
minor axis of the working plane. Input range 0 to
99999.9999
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Traversing to clearance height Q301: definition
of how the touch probe is to move between the
measuring points:

0

: Move at measuring height between measuring

points

1

: Move at clearance height between measuring

points

NC blocks

5 TCH PROBE 414 DATUM INSIDE

CORNER
Q263=+37

;1ST POINT 1ST AXIS

Q264=+7

;1ST POINT 2ND AXIS

Q326=50

;SPACING IN 1ST AXIS

Q296=+95

;3RD POINT 1ST AXIS

Q297=+25

;3RD POINT 2ND AXIS

Q327=45

;SPACING IN 2ND AXIS

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q301=0

;MOVE TO CLEARANCE

Q304=0

;BASIC ROTATION

Q305=7

;NO. IN TABLE

Q331=+0

;DATUM