Cycle run, Please note while programming – HEIDENHAIN TNC 640 (34059x-05) Cycle programming User Manual

Page 539

Advertising
background image

MEASURE RECTANGLE INSIDE (Cycle 423, DIN/ISO: G423) 16.7

16

TNC 640 | User's Manual Cycle Programming | 1/2015

539

16.7

MEASURE RECTANGLE INSIDE
(Cycle 423, DIN/ISO: G423)

Cycle run

Touch Probe Cycle 423 finds the center, length and width of a
rectangular pocket. If you define the corresponding tolerance
values in the cycle, the TNC makes a nominal-to-actual value
comparison and saves the deviation value in system parameters.

1 Following the positioning logic, the TNC positions the touch

probe at rapid traverse (value from

FMAX column) (see

"Executing touch probe cycles", page 444) to touch point

1

. The

TNC calculates the touch points from the data in the cycle and
the safety clearance from the

SET_UP column of the touch

probe table.

2 Then the touch probe moves to the entered measuring height

and runs the first probing process at the probing feed rate
(column

F).

3 Then the touch probe moves either paraxially at measuring

height or at clearance height to the next starting point

2

and

probes the second touch point.

4 The TNC positions the probe to starting point

3

and then to

starting point

4

to probe the third and fourth touch points.

5 Finally the TNC returns the touch probe to the clearance height

and saves the actual values and the deviations in the following
Q parameters:

Parameter number

Meaning

Q151

Actual value of center in reference axis

Q152

Actual value of center in minor axis

Q154

Actual value of length in the reference
axis

Q155

Actual value of length in the minor axis

Q161

Deviation at center of reference axis

Q162

Deviation at center of minor axis

Q164

Deviation of side length in reference
axis

Q165

Deviation of side length in minor axis

Please note while programming:

Before a cycle definition you must have programmed
a tool call to define the touch probe axis.

If the dimensions of the pocket and the safety
clearance do not permit pre-positioning in the
proximity of the touch points, the TNC always starts
probing from the center of the pocket. In this case
the touch probe does not return to the clearance
height between the four measuring points.

Advertising