Figure c – HEIDENHAIN PWM 20 User Manual

Page 54

Advertising
background image

August 2014

Overview of cables and adapters

55

Figure C

Measured at the control input (25-pin speed encoder input):

Note

Linear and torque drives operate with incremental encoders without commutation
signal (encoder connector M23, 12-pin). Temperature sensor information is input in addition
via the voltage controller ID 383951-01 (17-pin output flange socket). The shown adapter
cables are also used in figure A.

Note

Linear or angle encoders on linear motors (direct drives) provide the actual value for both the
position controller and the speed controller. In this application the position encoders are
operated at the motor controller input of the NC!

Linear and torque drives

Incremental commutation

1 Vpp