11.3 List of Parameters

11-23

11

Appendix

* When Pn50A.0 is set to 0 for the input signal standard allocation mode, the following modes are compatible:

Pn50A.1 = 7, Pn50A.3 = 8, and Pn50B.0 = 8.

Parameter

No.

Name

Setting Range

Unit

Factory

Setting

Setting

Validation

Pn50A

Input Signal Selections 1

2100

After restart

0

1

2

3

4

5

6

7

8

9

A

B

0

1

ON when CN1-40 input signal is ON (L-level).

ON when CN1-41 input signal is ON (L-level).

ON when CN1-42 input signal is ON (L-level).

ON when CN1-43 input signal is ON (L-level).

ON when CN1-44 input signal is ON (L-level).

ON when CN1-45 input signal is ON (L-level).

ON when CN1-46 input signal is ON (L-level).

Sets signal ON.

Sets signal OFF.

OFF when CN1-40 input signal is OFF (H-level).

OFF when CN1-41 input signal is OFF (H-level).

OFF when CN1-42 input signal is OFF (H-level).

OFF when CN1-43 input signal is OFF (H-level).

OFF when CN1-44 input signal is OFF (H-level).

OFF when CN1-45 input signal is OFF (H-level).

OFF when CN1-46 input signal is OFF (H-level).

/S-ON Signal Mapping
Signal Polarity: Normal; Servo ON when ON (L-level)
Signal Polarity: Reverse; Servo ON when OFF (H-level)

0 to F Same as /S-ON

/P-CON Signal Mapping (P control when ON (L-level))

4th
digit

3rd
digit

2nd
digit

1st
digit

n.

C

D

E

F

Uses the sequence input signal terminals with standard allocation.∗

Changes the sequence input signal allocation for each signal.

Input Signal Allocation Mode

P-OT Signal Mapping (Overtravel when OFF (H-level))

0

1

2

3

4

5

6

7

8

9

A

B

Forward run allowed when CN1-40 input signal is ON (L-level).

Forward run allowed when CN1-41 input signal is ON (L-level).

Forward run allowed when CN1-42 input signal is ON (L-level).

Forward run allowed when CN1-43 input signal is ON (L-level).

Forward run allowed when CN1-44 input signal is ON (L-level).

Forward run allowed when CN1-45 input signal is ON (L-level).

Forward run allowed when CN1-46 input signal is ON (L-level).

Forward run prohibited.

Forward run allowed.

Forward run allowed when CN1-40 input signal is OFF (H-level).

Forward run allowed when CN1-41 input signal is OFF (H-level).

Forward run allowed when CN1-42 input signal is OFF (H-level).

Forward run allowed when CN1-43 input signal is OFF (H-level).

Forward run allowed when CN1-44 input signal is OFF (H-level).

Forward run allowed when CN1-45 input signal is OFF (H-level).

Forward run allowed when CN1-46 input signal is OFF (H-level).

C

D

E

F