4 regenerative resistor units – Yaskawa Sigma II Series SGMVH User Manual

Page 33

Advertising
background image

2.5 Selecting Peripheral Devices

2

Selections

2-9

2.5.3 Noise Filters, Magnetic Contactors, and Brake Power Supply Units

Note: 1. If some SERVOPACKs are wired at the same time, select the proper magnetic contactors accord-

ing to the total capacity.

2. The following table shows the manufacturers of each device.

2.5.4 Regenerative Resistor Units

SERVOPACK Model

Recommended Noise Filter

Magnetic Contactor

Brake Power Supply Unit

SGDM-2BADB
SGDH-2BAEB

FN258L-130-35

SC-N6 (125A)

c24 VDC brake (provided by a
customer)

d90 VDC brake

• LPDE-1H01 for 100 VAC input
• LPSE-2H01 for 200 VAC input

SGDM-3ZADB
SGDH-3ZAEB

FN258L-180-07

SC-N8 (180A)

SGDM-3GADB
SGDH-3GAEB

FN359P-250-99

SC-N10 (220A)

SGDH-2BDEB

FN258L-180-07

SC-N6 (125A)

SGDH-3ZDEB

FN258L-180-07

SC-N8 (180A)

SGDH-3GDEB

FN258L-180-07

SC-N8 (180A)

SGDH-4EDEB

FN359P-250-99

SC-N10 (220A)

SGDH-5EDEB

FN359P-250-99

SC-N10 (220A)

SGDH-9ZDEB

FN359P-300-99

SC-N11 (300A)

Peripheral Device

Manufacturer

Noise Filter

Schaffner Electronic

Magnetic Contactor

Fuji Electric Co., Ltd.

Brake Power Supply
Unit

Yaskawa Controls Co., Ltd.

SERVOPACK

Model

SGDM- 2BADB 3ZADB 3GADB

SGDH-

2BAEB

3ZAEB 3GAEB 2BDEB 3ZDEB 3GDEB 4EDEB 5EDEB 9ZDEB

Regenerative
Resistor Unit
Model

JUSP-

RA08

RA09

RA11

RA12

RA13

RA14

RA15

RA16

RA25

Resistance (

Ω)

2.4

1.8

1.6

9

6.7

5

4

3.8

2.1

Resistance
Capacity (W)

2400

4800

4800

3600

3600

4800

6000

7200

16800

Allowable Load Moment of
Inertia (

×10

-4

kg·m

2

)

1830

2490

2875

1830

2490

2875

5355

6450

9020

Allowable Duty

2% ED at maximum speed and torque deceleration.

Advertising