Yaskawa Sigma II Series SGMVH User Manual

Page 45

Advertising
background image

3 Servomotor Specifications and Dimensional Drawings

3.3.1 Precautions on Servomotor Installation

3-10

1. Before starting installation, thoroughly remove the anticorrosive paint that coats the end of the motor

shaft.

2. Vibration from improper alignment of shafts will damage the bearings.
3. Do not allow direct impact to be applied to the shafts when installing the coupling as the encoder

mounted on the opposite end of the shaft may be damaged.

Handling Oil
and Water

If the servomotor is used in a location that is subject to
water drops, make sure of the servomotor protective
specifications (except for through shaft section).
If the servomotor is used in a location that is subject to
water or oil mist, use a servomotor with an oil seal to
seal the through shaft section.

Precautions on Using Servomotor With Oil Seal

• The oil surface must be under the oil seal lip.
• Use an oil seal in favorably lubricated condition.
• When using a servomotor with its shaft pointed

upward, be sure that oil will not stay in the oil seal
lips.

Cable Stress

Make sure there are no bends or tension on the power lines.
Especially be careful to wire signal line cables so that they are not subject to stress because the core
wires are very thin at only 0.2 to 0.3 mm.

Connectors

Observe the following precautions:

• Make sure there is no foreign matters such as dust and metal chips in the connector before connect-

ing.

• When the connectors are connected to the motor, be sure to connect the end of servomotor main cir-

cuit cables before connecting the encoder cable’s end.
If the encoder cable’s end is connected first, the encoder may be damaged because of the voltage dif-
ferences between frame grounds.

• Make sure of the pin arrangement.
• Do not apply shock to resin connectors. Otherwise, they may be damaged.
• When handling a servomotor with its cables connected, hold the servomotor or the connectors.

Otherwise, the cables will be damaged.

• When bending cables are used, wiring must be performed so that excessive stress will not be applied

to the connector section. Failure to observe this caution may damage the connector.

Through shaft section:

Shaft

Flange

This refers to the gap where
the shaft protrudes from
the end of the motor.

IMPORTANT

Anticorrosive
paint is
coated here.

Advertising