A-1 Appendix

Optional Accessories for the ME-AGS-S

The following two Pigtail Adapters are available from Magnum Energy for

use with the ME-AGS-S. They are

useful in applications where there is a

requirement to conveniently and automatically turn the generator on/off

externally through a manually controlled switch or from an automatically

controlled switching device

(i.e., use air conditioner thermostat controls to

turn gen on to run air conditioner):

The ME-PT1 (Pigtail One-wire) adapter is designed to allow the AGS to start

the connected generator when an external +12 volt DC supply is applied.
The ME-PT2 (Pigtail Two-wire) adapter is designed to allow the AGS to start

the connected generator by an external two-contact switch.

Additional Magnum Equipment/Accessories

The following components are also available from Magnum Energy:

MS Series Inverter/Chargers
The MS Series inverter/charger is a pure sine wave inverter designed

specifi cally for mobile and off-grid applications. The MS Series has a built-in

PFC (Power Factor Corrected) charger that uses 25-30% less AC current than

standard chargers. The MS Series also provides multiple ports, including an

RS485 communication port for network expansion, and a remote port.

MMP Series Enclosures

The MMP175-30D, MMP175-60S, MMP250-30D, and MMP250-60S enclosures

are specifi cally designed for single inverter applications. The MMP Series en-

closures combine all of the major components required for a renewable energy

system—inverter/battery disconnect, AC overcurrent protection, grounding

connections, and a full system inverter bypass—into a single, easy to install

pre-wired enclosure.

Advanced Remote Control Display
The ME-ARC allows advanced features of the Magnum inverter or accessory to

be confi gured. This LCD remote display includes a FAVS button to access your

favorite features quickly and provides advanced monitoring/troubleshooting.
Basic Remote Control Display
The ME-RC remote control is simple to use; an easy-to-read LCD screen

and “at a glance” LEDs display complete inverter/charger status. Soft keys

provide simple access to menus and a rotary encoder knob allows you to

scroll through and select a wide range of settings such as INVERTER ON/OFF,

CHARGER ON/OFF, SHORE power breaker setting, AGS control, and METER,

SETUP, and TECH menus.
Battery Monitor

The Battery Monitor Kit (ME-BMK) is a single battery bank amp-hour meter

that monitors the condition of the battery and provides information to let

you know how much energy you have available. It also lets you plan your

electrical usage to ensure the battery is not being over-discharged.
Fuse Block/Fuses

The Magnum fuse/fuse-blocks are used to protect the battery bank, inverter,

and cables from damage caused by DC short circuits and overloads. They

include a slow-blow fuse with mounting block and protective cover. The 125

and 200-amp models use an ANL type fuse and the 300 and 400-amp models

use a Class-T fuse.