2 required components and tools, 3 mounting procedure, Installation – Magnum Energy AGS Stand Alone (ME-AGS-S) User Manual

Page 9

Advertising
background image

© 2013 Magnum Energy, Inc.

6

2.2

Required Components and Tools

2.2.1

List of supplied components in the ME-AGS-S:

• ME-AGS-S Owner’s Manual
• AGS controller (with four #8 x 3/4” Phillips mounting screws)
• AGS switch/bezel (with two #6 x 1” Phillips mounting screws)
• 25 ft communications cable

2.2.2

List of other required equipment and materials:

• 16 to 12 AWG wire for connecting the ME-AGS-S to the generator start/

stop circuit and to the battery bank
• In-line fuse holders (with 5-amp DC fuse)

2.2.3

Tools that may be required to install the ME-AGS-S:

• Phillips screwdriver (#2)
• Flat-blade screwdrivers

(1/4” and 1/8” blades)

• Wire stripper
• Cut-out tool (knife/saw)
• Drill bits (7/64” & 1/8”)

• Drill
• Level
• Pencil

2.3 Mounting

Procedure

2.3.1

Mounting the AGS Controller

1. Select a location that is clean, dry, and protected from extreme

temperatures to mount the controller. Wiring is much easier if the

controller is mounted within easy access to the generator’s remote

switch wiring. Refer to Figure 2-2 for the controller’s dimensions.

Info: The controller/switch can be mounted in any direction. However,

allow ample room to access the switch and the adjustment dials, and

to view the LEDs for operational status and troubleshooting.

2. Remove the green 8-pin friction fi t connector from the controller by

pulling it straight out. Wait to plug this 8-pin connector back into the

AGS controller until after the installation is completed and the AGS

functional tests are performed in Section 3.3.

3. Mount the AGS controller using the four #8 x 3/4” screws provided.
2.3.2

Mounting the AGS Remote Switch

1. Select a location that is convenient, clean, dry, and protected from

extreme temperatures to mount the remote switch.

Info: The temp sensor used to activate the temperature turn-on

feature is located on the back of the AGS switch. If using the tem-

perature turn-on feature, the switch must be placed where the room

temperatures can be accurately determined by the sensor. DO NOT

mount the switch near window drafts, or heating and air conditioning

ducts, and avoid mounting it on exterior walls.

2. Cut a hole for the switch. See Figure 2-3 for switch and cutout dimensions.
3. Plug the communications cable into the RJ12 connector on the back of

the AGS switch (Section 2.4), and then feed the communication cable

(6-conductor data cable) through the opening and route it to the AGS.

Info: Use care in routing the cable to ensure the cable does not

become pinched or cut by rough or sharp edges. Leave enough slack

to allow movement of the cable once the installation is complete.

4. Mount the switch with its bezel to the wall using the two #6 x 1” screws

provided.

Installation