Maintenance, Installing valve, Removing valve – CarAlarms.com P90-NG1 User Manual

Page 46

Advertising
background image

Excalibur

®

P90 Zero Clearance Direct Vent Gas Fireplace

46

12) Undo the pilot tube from the valve with a
7/16"

wrench.

13) Undo the quick drop out thermocouple nut

on the valve with a 9mm (metric) wrench.

14) Remove the Piezo igniter wire and push

button assembly.

15) Undo the "gas out" fl are nut with a 13/16"

wrench.

16) Undo the "gas out" fl are fi tting with an
11/16"

wrench.

17) Remove the 4 Phillips head screws from

the sides of the valve bracket and remove
valve.

Hint:

If you are using black pipe, ensure
that there is a union by the valve,
otherwise removal will be almost
impossible.

INSTALLING VALVE

1) Attach the valve to the valve bracket with

the 4 (m5x8 metric) screws provided.

2) Reconnect the "gas out" fl are fi tting with an

11/16" wrench.

3) Reconnect the "gas out" fl are nut with a

13/16" wrench.

4) Install piezo ignitor push button assembly

and reconnect wire.

5) Reconnect the quick drop out thermocouple

nut with a 9mm wrench.

6) Reconnect the pilot tube nut with a 7/16"

wrench.

7) Scrape off the old gasket from the fl oor of the

fi rebox and from the valve tray assembly.

8) Install a new gasket and reinstall the valve

tray assembly.

Note: Failure to install a new gasket may
severely affect the appliance performance.

9) Reinstall the 10 hold down screws.

10) Hook up the 2 TP and 2 TH wires to the

appropriate connections on the valve.

11) Reinstall the bottom brick panel, then screw

the 2 screws & sleeves through the brick
panel to the fi rebox base (reversing step 8)
leaving them about 1/4" (6mm) above the
brick panel. Reinstall the rear log stand.

12) Install Burner/grate assembly

13) Hook up the gas line and check for gas

leaks with a soap and water solution or a
gas leak detector. (Do not use open fl ame
for leak testing.)

14) Fire up the unit temporarily

15) Check the manifold pressure.

16) Reinstall the logs and brick panels as

needed.

17) Reinstall the glass door and the facade.

18) Fire up the unit again and check for proper

fl ame appearance and glow on logs.

REMOVING VALVE

1) Shut the power off.

2) Open the bottom louver door. Loosen the 2

screws holding the Burner ON/OFF switch
and bracket to the bottom louver and lift the
assembly out.

3) Remove

the

facade

if

installed.

4) Remove the glass door (Refer to the "Glass

Door Installation" section).

5) Remove the logs.

6) Remove the burner/grate assembly by

removing the two Phillips head screws and
then slide the burner assembly to the left
and lift out.

Diagram 1: Remove the left and right screws

and then slide the burner/grate assembly to

the left and lift out.

7) Remove the rear log stand by removing the

2 screws.

Rear Log Stand

screws

9) Disconnect the inlet gas line. See dia. 2.

10) Disconnect the 2 TP wires and the 2 TH

wires from the valve.

11) Remove the 12 Phillips head screws securing

the valve tray assembly in place and then
lift the entire assembly out.

screws

Valve Tray Assembly

8) Remove the 2 screws & sleeves on the

bottom brick panel and lift out the bottom
brick panel. The brick panel is very fragile
- handle with care.

screws

MAINTENANCE