Remote connection

d

RS-232 connector — Connect a host device, such as a computer or control

system, to the switcher via this 9-pin D connector (figure 2-5) for remote

control of the switcher.

Pin

RS-232

Function

1

Not used

2

TX

Transmit data (-)

3

RX

Receive data (+)

4

Not used

5

Gnd

Signal ground

6

Not used
Not used
Not used

7

8


5

1

9

6

Female

Hardwired IR

9

Figure 2-5 — RS-232 port pin assignment

N

The cable used to connect the RS-232 port to a computer or control system

may need to be modified by removing pins or cutting wires. If you encounter
problems while operating under RS-232 control (the switcher may hang up),
pins 1, 4, 6, 7, and 8 may need to be disconnected. Either cut the wire to
pins 1, 4, and 6 through 8 in a hard-shelled connector or remove pins 1, 4, and
6 through 8 from a molded plug.

See chapter 4, “Remote Operation”, for definitions of the SIS commands and

details on how to install and use the control software.

Using the hardwired IR input on pin 9, you can use a control system with

IR-learning capabilities to operate the switcher just as if you were using an

IR 501 remote control. The control system must first “learn” the IR command

from an IR 501, after which it sends the same commands to the MVX via pin 9.

Power connection

5

AC power connector — Plug a standard IEC power cord into this connector to

connect the switcher to a 100 VAC to 240 VAC, 50 or 60 Hz power source.