MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Remote Operation

4-2

Remote Operation

PRELIMINAR

Y

The MVX VGA Series switchers can be remotely controlled via the switcher’s rear

panel RS-232 connector (figure 4-1) or using an optional infrared Small Matrix

Universal Remote Control (figure 4-2).

Pin

RS-232

Function

1

Not used

2

TX

Transmit data (-)

3

RX

Receive data (+)

4

Not used

5

Gnd

Signal ground

6

Not used
Not used
Not used

7

8


5

1

9

6

Female

Hardwired IR

9

Figure 4-1 — Remote connector pinout

SMALL MA

TRIX REMO

TE

INPUT/OUTPUT SELECTION

1

2

3

4

5

6

7

8

PRESET

SA

VE

VIDE

O

A

UDI

O

MUTE

UNMUT

E

INPUT

OUTPU

T

9

0

+10

ENTER

IR 501

IR

2

1

3

Extron
IR 501 Remote, Part # 70-336-01

Figure 4-2 — Small matrix IR remote control

The RS-232 protocol is 9600 baud, 8-bit, 1 stop bit, no parity, and no flow control.

RS-232 remote control devices can be either a host device, such as a computer or a

control system.

N

When using communications software such as HyperTerminal to control the

MVX switcher, verify that the terminal emulation is set to Auto Detect or ANSI
and set flow control to None. Other settings may cause errors.

Two remote control methods are available: Extron’s Simple Instruction Set and

Extron’s Windows

®

-based Matrix Switchers Control Program.

Operation of the IR 501 remote control is described in the IR 501 Small Matrix IR

Remote Control User’s Guide

.

Using the hardwired IR input on pin 9, you can use a control system with

IR-learning capabilities to operate the switcher just as if you were using an IR 501

remote control. The control system must first “learn” the IR command from an

IR 501, after which, it sends the same commands to the MVX via pin 9.

Simple Instruction Set Control

Host-to-Switcher instructions

The switcher accepts SIS (Simple Instruction Set) commands through the RS-232

port. SIS commands consist of one or more characters per command field. They do

not require any special characters to begin or end the command character sequence.

Each switcher response to an SIS command ends with a carriage return and a line

feed (CR/LF =

]

), which signals the end of the response character string. A string

is one or more characters.