Resetting the system to factory defaults, Memory, Preliminar y – Extron electronic MVX 88 Series User Manual

Page 43

Advertising
background image

3-25

MVX 44 / 48 / 84 / 88 VGA Matrix Switchers • Operation

PRELIMINAR

Y

Resetting the system to factory defaults

To reset a switcher to the factory default settings, press and hold the I/O button

on the front panel while applying AC power (figure 3-42). Continue to hold the

I/O button until all LEDs light and then release the I/O button. The power up

sequence completes (all LEDs turn off then turn on and off from left to right, the

Video and Audio LEDs turn on, and all other LED remain off). System reset does

the following:

• Clears all ties and presets.
• Clears all video and audio mutes.
• Sets all input audio gain levels to their default (0 dB) values.
• Returns the output audio level to the professional (+4 dBu) level.

I / O

I/O

AUD

VID

I/O

AUD

VID

Press and

hold the I/O button while

you apply power to the switcher.

Power

I/O

AUD

AUDIO SETUP

PRESET

VID

+dB

-dB

1

1

The switcher lights

all of the LEDs.

The switcher continues the power up process.

Release the I/O button.

Figure 3-42 — System reset to factory defaults

Memory

The current configuration, all presets, and all input audio levels are saved in non-

volatile memory within 5 seconds of a change or exiting Audio Setup mode. When

power is applied, the last current configuration is retrieved. The previous presets

remain intact.
N

Wait at least 5 seconds after changing any configuration, saving a preset, or

exiting

Audio Setup mode. Before 5 seconds have elapsed, changes that you

have made may not have been saved.