Emerson 1F92 User Manual

Page 16

Advertising
background image

14

INSTALLER CONFIGURATION (cont.)

INSTALLER CONFIGURATION (cont.)

INSTALLER CONFIGURATION (cont.)

INSTALLER CONFIGURATION (cont.)

INSTALLER CONFIGURATION (cont.)

To exit the menu at any time, press
PROGRAM

RUN

.

MULTI-STAGE/HEAT PUMP

MULTI-STAGE/HEAT PUMP

MULTI-STAGE/HEAT PUMP

MULTI-STAGE/HEAT PUMP

MULTI-STAGE/HEAT PUMP
MODE.

MODE.

MODE.

MODE.

MODE.

(Installer table step 1.) Use this item
to select the system type (multi-
stage or heat pump). IF YOU
HAVE A HEAT PUMP SYSTEM
,
you must select HEAT PUMP here.
This sets up proper default values
for most heat pump systems. This
selection also makes available some
additional menu items that apply
only to heat pump systems.

HEAT PUMP COMPRES-

HEAT PUMP COMPRES-

HEAT PUMP COMPRES-

HEAT PUMP COMPRES-

HEAT PUMP COMPRES-
SOR CONFIGURATION.

SOR CONFIGURATION.

SOR CONFIGURATION.

SOR CONFIGURATION.

SOR CONFIGURATION.

(Installer table step 2; this menu
item is displayed only when heat
pump was selected in step 1.) Use

this item to select the number of
heat pump compressors and how
they are connected.

ELECTRIC HEAT FAN

ELECTRIC HEAT FAN

ELECTRIC HEAT FAN

ELECTRIC HEAT FAN

ELECTRIC HEAT FAN
CONFIGURATION.

CONFIGURATION.

CONFIGURATION.

CONFIGURATION.

CONFIGURATION.

(Installer table step 3.) This menu
item determines whether fan control
will be through the thermostat or
through the heating system. If you
have an electric heat or other system
that REQUIRES the thermostat to
control the fan, set this item ON.
This allows the thermostat to
energize the fan immediately on a
call for heat. If you are unsure if the
system requires the thermostat to
control the fan, contact the equip-
ment manufacturer or a qualified
heating and air conditioning service
person. If your system controls fan

operation (as with most fossil fuel
systems), set this item to OFF. Note
that with heat pump systems, the fan
always cycles with the compressor.

SET CYCLE HEAT, COOL,

SET CYCLE HEAT, COOL,

SET CYCLE HEAT, COOL,

SET CYCLE HEAT, COOL,

SET CYCLE HEAT, COOL,
AUX (ANTICIPATION).

AUX (ANTICIPATION).

AUX (ANTICIPATION).

AUX (ANTICIPATION).

AUX (ANTICIPATION).

(Installer table steps 4 through 6;
step 6 is for heat pump only). These
items allow the cycle times in
heating, cooling and auxiliary (heat
pump systems only) to be increased
or decreased. The factory set values
can be adjusted higher for longer
cycles or lower for shorter cycles.

NOTE: Some manufacturers still
instruct you to set the anticipator to
the current draw of the equipment.
That instruction applies only to
mercury bulb or mechanical
thermostats; it does not apply to

Advertising