Model 218a electronics setup, Model 218a electronics setup -2, World class 3000 – Emerson WORLD CLASS 3000 User Manual

Page 26

Advertising
background image

Instruction Bulletin

106-300NE Rev. 3.4
May 2000

3-2 Setup

Rosemount Analytical Inc. A Division of Emerson Process Management

World Class 3000

NOTE

The voltage given above is for an am-
bient (machinery space) temperature
of 77°F (25°C). For each degree of am-
bient temperature above or below 77°F
(25°C), add or subtract 0.242 mV from
the nominal. Example; at 87°F (31°C),
the nominal voltage of -322.3 should
be increased (made less negative) by
10 x 0.242 or 2.42 mV, making the ad-
justed nominal -319.9.

f. Remove voltmeter leads.

g. Remove jumper wire.

3-3

MODEL 218A ELECTRONICS SETUP

Before beginning operation, it is important that
the probe heater set point of the existing elec-
tronics be changed to support the World Class
3000 probe. To convert the Model 218A Digital
Electronics Package for use with the World
Class 3000 Probe and Heater Power Supply,
an EPROM change is necessary. Remove Main
PCB and check back of board to identify unit as
G02 or G04. The replacement EPROM needed
is as identified below:

G02

G04

United States

1M03192G01

1M02982G01

United Kingdom

1M03192G02

1M02982G02

Germany

1M03192G03

1M02982G03

France

1M03192G04

1M02982G04

Italy

1M03192G05

1M02982G05

NOTE

The replacement EPROM when using a
multiprobe averager unit is
1M02982G10.

To replace the EPROM, proceed as follows:

a. Shut off and lock out power to the electron-

ics package.

b. Open electronics enclosure.

c. On the Main PCB, Figure 3-2, locate and

remove old EPROM.

d. Replace with new EPROM.

e. Close electronics enclosure and power up

system.

Figure 3-2. Main PCB (Model 218A) EPROM Replacement

Advertising