Enterasys Networks 2E43-27 User Manual

Page 53

Advertising
background image

Device Events and Alarms

Event and Alarm Messages

Fast Ethernet SmartSwitch Module

4-2

Management Module Guide

CsEvFormat/Event00010308

{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected a
communication Link Down. (event
[{e}])

CsPCause/Prob00010308

Communication link is down.

CsEvFormat/Event00010309

{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected a
communication Link Up. (event [{e}])

No probable cause message

CsEvFormat/Event0001030a

{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected an
Authentication Failure. (event [{e}])

CsPCause/Prob0001030a

Authorization failure. Other user is trying to
connect to device with an invalid community
string.

CsEvFormat/Event0001030b

{d “%w- %d %m-, %Y - %T”} - A(n) {t}
device, named {m}, has detected an
EGP Neighbor Loss. EGP Neighbor
IP address is {0 1}. (event [{e}])

CsPCause/Prob0001030b

Lost contact with EGP neighbor.

CsEvFormat/Event000d01a0

{d “%w- %d %m-, %Y - %T”} - A Port
Interface Module has been inserted
into port {I 3} of interface {I 1} on {m}
({t}). (event [{e}]).

CsPCause/Prob000d01a0

A Port Interface Module has been physically
inserted.

CsEvFormat/Event000d01a1

{d “%w- %d %m-, %Y - %T”} - A Port
Interface Module has been removed
from port {I 3} of interface {I 1} on
{m} ({t}). (event [{e}])

CsPCause/Prob000d01a1

A Port Interface Module has been physically
removed.

CsEvFormat/Event000d01a2

{d “%w- %d %m-, %Y - %T”} -
Network configuration change
reported by {m} ({t}). Device linked to
port {I 3} on interface {I 1}. (event
[{e}])

CsPCause/Prob000d01a2

A device supporting link integrity, fiber optic or
twisted pair, has made a valid connection (link)
to this port.

Table 4-1.

Fast Ethernet SmartSwitch Module Events and Alarms (Continued)

Message in the Event Log

Alarm Manager Probable Cause

Message

Advertising
This manual is related to the following products: