Connecting to the Network

3-8

Hardware Installation

Figure 3-6

Device, Rear View

3. Observe that the power (RPS) LED (not shown), located on the front panel, turns ON (green)

and the CPU turns red until the device completes its initialization. It takes under 30 seconds for
the device to boot up.

4. If you are installing an optional redundant power system (RPS), refer to the Matrix C Series

Redundant Power System Installation Guide supplied with the RPS. The RPS chassis is
connected to the 15-pin D-type connector

using a DC Power/Monitor cable.

3.5

CONNECTING TO THE NETWORK

The following procedures cover the cable connections from the network or other devices to either
the C1H124-48 or C1G124-24 any installed optional Mini-GBIC.

Connecting UTP Cables (

Section 3.5.1

)

Connecting Fiber-Optic Cables to Mini-GBICs (

Section 3.5.2

)

AC power cord

AC power outlet

AC power receptacle

D-type connector for external redundant power supply

NOTE: If the power-up sequence is interrupted on this device, or if optional hardware
has been installed or removed, this device may run an extended diagnostics sequence
that may take up to two minutes to complete.

3831_01_06