Enterasys Networks C1H124-24 User Manual

Page 55

Advertising
background image

Using LANVIEW

Troubleshooting

4-3

RPS

Off

No power indicated by
either the internal or a
connected external power
supply, or

there is no power
redundancy available
from the external power
supply.

1. Ensure that the power cords are plugged in

correctly and that there is power at the two
power sources.

2. If an external power supply is connected

to the C1H124-48, note the display of its
LED indicators for power status
indications. Correct problem as necessary.

3. Contact Enterasys Networks for technical

support.

Green

Blinking. No power
redundancy from the
external power supply, or

the internal power supply
failed or is not receiving
ac power. However, there
is power redundancy
from the external power
supply.

1. Ensure that the power cords are plugged in

correctly and that there is power at the two
power sources.

2. Contact Enterasys Networks for technical

support.

Solid. Power redundancy
is available from external
power supply. The
system is powered by
either the internal or
external power supply.

None.

Link/
Activity

Off

No link.
No activity or port in
standby.

None.

Green

Solid. Port is linked, but
the interface is not
receiving any traffic.

None.

Blinking. Port linked and
traffic is being received or
transmitted by the
interface.

None.

Table 4-1

LANVIEW LEDs (Continued)

LED

Color

State

Recommended Action

Advertising
This manual is related to the following products: