A.4 console port pinout assignments, A.5 regulatory compliance, Console port pin assignments – Enterasys Networks C1H124-24 User Manual

Page 64: Compliance standards, Section a.4, Section a.5

Advertising
background image

Console Port Pinout Assignments

A-6

Specifications

A.4

CONSOLE PORT PINOUT ASSIGNMENTS

The Console port is a serial communications port that supports local management of the C1H124-48
and C1G124-24. These pin assignments differ from other Enterasys products. Refer to

Table A-7

for the Console port pin assignments.

A.5

REGULATORY COMPLIANCE

The C1H124-48 and C1G124-24 meet the safety and electromagnetic compatibility (EMC)
standards listed in

Table A-8

:

Table A-7

Console Port Pin Assignments

Pin

Signal Name

Input/Output

1

Transmit Data (TD)

Output

2

Clear to Send (CTS)

Input

3

Data Set Ready (DSR)

Input

4

Receive Data (RD)

Input

5

Signal Ground (GND)

NA

6

Request to Send (RTS)

Output

7

Data Terminal Ready (DTR)

Output

8

Data Carrier Detect (DCD)

Input

Table A-8

Compliance Standards

Compliance Standards

Safety

UL 60950, CSA C22.2 No. 60950, EN 60950,
73/23/EEC and IEC 60950. The 7G-6MGBIC also
meets the EN 60825, 21 CFR 1040.10 standards.

Electromagnetic Compatibility (EMC)

FCC Part 15, CSA C108.8, 89/336/EEC, EN 55022,
EN 61000-3-2, EN 61000-3-3, EN 55024,
AS/NZS 3548, VCCI V-3