Cold Drink Center (327/328) Operator’s Guide

3280020

Page 9

August, 2003

Set up the CO

2

tank:

NOTE

A full CO

2

tank can be dangerous if it is dropped or mishandled. Handle with care

and keep the tank lid in place until the tank is properly secured in the
merchandiser.

a. Place the power switch in the OFF position.
b. Install a full CO

2

tank on the merchandiser as shown. Secure the CO

2

tank with the retaining chain. (Note the various retaining chain configura-
tions.)

c. Remove the CO

2

tank lid. Briefly open and close the CO

2

cylinder valve

to blow out any foreign matter.

d. Locate the CO

2

regulator and flat plastic washer (in a box), and the

tapered plastic washer (in plastic bag).

e. Connect the CO

2

hose from the secondary regulator tee fitting to the reg-

ulator. Firmly tighten the fitting.

ADJUSTMENT

SCREW

CO CYLINDER

VALVE

2

ADJUSTMENT

LOCK NUT

CO HOSE

2

(REAR OF TANK SHOWN)

327p0008

CO CYLINDER

2

SYRUP TANKS

LOCATION 1

LOCATION 2

˜

CO CYLINDER

2

RETAINING

CHAIN

RETAINING

CHAIN

CO CYLINDER

2

LOCATION 1

RETAINING

CHAIN