9.

Setting the icemaker water level:
A proper level should be maintained within the icemaker. To determine the
water level, a label is located on the icemaker that indicates the proper level
in the melt-down tube. The icemaker water level is dependent upon the
feeder cup water level.
a. Set the MAIN SWITCH to the OFF (down) position.
b. Remove the water feeder cup cover.
c. Adjust the float shaft bushing:

UP - to raise the water level.
DOWN - to lower the water level.

d. Replace the water feeder cup cover.
e. Check the new water level:

Set the MAIN SWITCH to the ON (up) position.

Press

, then

until the display shows

`^o_=qbpq

.

Press

to dispense still water; press

again to stop.

Press

. The feeder cup will refill after you leave the carbonator test.

When the feeder cup is full, press

to return to

`^o_=qbpq

.

When the water flow stops, check the water level in the melt-down tube.

f.

Repeat steps a through e until the water level is correct.

WATER LEVEL

SWITCH ACTUATOR

˜

WATER FEEDER

FLOAT SHAFT

FLOAT SHAFT

BUSHING

WATER FEEDER

FLOAT ASSEMBLY