Cold Drink Center (327/328) Operator’s Guide

3280020

Page 13

August, 2003

3.

Testing the water pump flow

The water pump should require between 13 and 21 seconds to completely refill
the carbonator. To check the water flow, proceed as follows:

a. Place a cup in the cup station and make sure the waste pail is in place.

b. Press

, then

until the display shows:

`^o_=qbpq

.

c. Press

. The water pump starts, and the display shows

bjmqvfkd=

while the carbonator dispenses, then shows

cfii=uu

as the carbonator

refills.

d. After adjusting the flow, repeat step c until the desired time is achieved.

4.

Adjusting the water pump flow:
a. Remove the cap nut to expose the adjustment screw.
b. Turn the adjustment screw:

CLOCKWISE to decrease refill time.
COUNTERCLOCKWISE to increase refill time.

NOTE

Failure to replace the cap nut will cause the water pump to leak.

c. Replace the cap nut.

5.

Adjusting the water valve:
The water valves are located under the water bath cover.

NOTE

To prevent personal injury, only turn the adjusting screw when
making adjustments. DO NOT loosen or remove the limit screw
located above the adjusting screw.

NOTE

See "Set Up A Drink" on page 36, for the procedure and table
for setting throws.

WATER

PUMP

CAP
NUT

ADJUSTING

SCREW