Cold Drink Center (327/328) Operator’s Guide

August, 2003

Page 62

3280020

VIEW CUP RING CYCLES RELATED TO SUREVEND™

(Not Shown If Zero)

1.

Press

, then press

until the display shows

SV.TOT XX

.

XX represents the number of vends during which more than one ring cycle
was required to successfully dispense a cup.

2.

Press

to clear the count.

3.

CONTINUE.

VIEW NUMBER OF CUP RING CYCLE FAILURES
(Not Shown If Zero)

1.

Press

, then press

until the display shows

SV.FL1 XX

.

XX represents the number of times a cup was not detected after ring 1
cycled. Check the cup ring adjustment (see "Cup mechanism
adjustment." on page 12
)
, or the cup stack for damage if the count is
excessive.

2.

Press

to clear the count.

3.

Press

until the display shows

SV.FL2 XX

. XX represents the number

of times a cup was not detected after ring 2 cycled. Check the cup ring
adjustment (see "Cup mechanism adjustment." on page 12), or the cup
stack for damage if the count is excessive.

4.

CONTINUE.

VIEW HOME SWITCH USE RELATED TO SUREVEND
(Not Shown If Zero)

1.

Press

, then press

until the display shows

WO.SV XX

.

XX represents the number of times home switches were used due to

OPT

N SURE.V

selected but not working.

2.

CONTINUE.