View surevend™ average calibration value, View surevend™ last recorded calibration value – Everpure 327 User Manual

Page 75

Advertising
background image

Cold Drink Center (327/328) Operator’s Guide

3280020

Page 69

August, 2003

On input screen #2, you can press the following letters to perform the indicated
operation:

A

Dispense ice (and turn on the icemaker compressor if the hop-
per is not full)

B

Force CO

2

valve on

C

Dispense carbonated water

D

Dispense still water

5.

Actuate each switch or sensor to test its function. As you actuate each input,
the display element representing that switch blinks on. Releasing the switch
causes that element to blink off again.

6.

CONTINUE.

VIEW SUREVEND™ AVERAGE CALIBRATION VALUE

1.

Press

, then press

until the display shows

CAL.AVE XXX

.

XXX represents the average sensor calibration value (should be between 50
and 255 for proper sensor operation - i.e. 51 through 254). Although this
number could go as low as 20, the SureVend™ system will be inoperative in
this condition.

2.

CONTINUE.

VIEW SUREVEND™ LAST RECORDED CALIBRATION
VALUE

1.

Press

, then press

until the display shows

CAL.LST XXX

.

XXX can be any number from 0 to 255, and represents the most recent
value read from the sensor. The lower the number, the greater the sensor
blockage. A number of 255 means that there is a fatal problem with the
SureVend™ interface board. Ensure the SureVend™ interface PCB is
properly connected to the main controller PCB.

2.

CONTINUE.

Advertising
This manual is related to the following products:

325