Initial installation – Enviro Sonnet C-11253 User Manual

Page 20

Advertising
background image

Figure 33: Spill Switch Wires Fed

Through Back Panel.

Initial Installation

QUALIFIED INSTALLERS ONLY

Figure 34: Remove Jumper

From Thermocouple.

Figure 35: Spill Switch Wires Connect

to Thermocouple.

Figure 36: Remove Flue Slider Plate & Gasket.

Figure 37: Install Spill Switch on

Bracket.

f) Re-attach the back panel.

g) Using a T-20 screwdriver

remove the four (4) screws that

hold the flue slider bottom plate.

Pull the plate down then out,

ensuring that the gasket comes

with the plate (see Figure 36).

h) Install spill switch bracket with

two (2) of the screws removed

in the previous step. The spill

switch must be angled under the

opening (see Figure 37)

20

Figure 32: Install of Intake Air Plug.

2. Install spill switch assembly.

a) Use a flat head screwdriver or 1⁄4” socket to remove the nine (9) screws holding the back cover on

(see Figure 46).

b) Cut the tie strap from around the wires for the spill switch.

c) Feed the connector end of both wires through the hole in the bottom left corner of the back panel

(see Figure 33).

d) Using needle nose pliers remove the Thermocouple Cable #1 (connector closer to the rear of the

unit) from the Thermocouple (see Figure 34 & 45).

e) Attach the female spill switch connector to the thermocouple and the male spill switch connector to

the Thermocouple Cable #1 (see Figure 35 & 45).

Advertising
This manual is related to the following products: