Kit Contents:

Quantity Description

1

Wall Bracket (Top & Bottom)

1

Spacer

1

Countersink Head Screw

2

Pan Head Screw

2

Spacer

55: Wall Bracket Installation

Option 1.

Figure 56: Wall Bracket Installation

Option 2.

Figure 57: Wall Bracket

Installation Option 3.

Note: The spacer maybe found between the top and

bottom halves of the wall bracket.

IMPORTANT: The remote handset wall

bracket must be installed in the same

room as the Sonnet.

Initial Installation

QUALIFIED INSTALLERS ONLY

A

DJUSTING

T

HE

P

ILOT

F

LAME

:

29

Installation Options:

1. Mounted to wall with bottom of

bracket only; refer to Figure 55.

2. Mounted to wall with top and

bottom of bracket; refer to Figure

56 (most common).

3. Mounted to wall and bottom of

light switch cover with top and

bottom of mount; refer to Figure

57.

The pilot flow adjustment is pre-set to maximum at the factory and

should not need to be adjusted. The pilot flame should envelope

3⁄8” to 1⁄2” (10 to 13mm) of the thermocouple (see Figure 53).

However, should the need arise, follow Steps 1- below.
1. Follow steps 1-4 in R

EMOVING

V

ALVE

C

OVER

- M

AINTENANCE

A

ND

S

ERVICE

.

2. If a fan is installed; unhook the three (3) connectors to the fan

motor, lift the fan up and off the grommets, and slide the fan

forward then up and out of the unit.

3. The adjustment screw can be reached through the 1⁄8” (3mm)

hole in the MAN-knob pointed out in Figure 54. The MAN-knob

must be in the ON position.

4. Pierce through the film on the cover with a screw driver to reach

the adjustment screw beneath.

5. Turn the adjustment screw clockwise to decrease or

counterclockwise to increase pilot flame.

Figure 54: Screw for Adjusting Pilot

Flame.

Figure 53: Proper Pilot Flame.