For your safety read before operating, Dvc-35ipt intermittent pilot lighting instructions – Empire Products DVC-35T-1 User Manual

Page 13

Advertising
background image

13119-6-0107

Page 13

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A. This appliance is equipped with an ignition de-

vice which automatically lights the pilot.

Do not try to light the pilot by hand.

B. BEFORE OPERATING smell all around the appliance

area for gas. Be sure to smell next to the floor because

some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch;

do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to slide the gas control knob. Never

use tools. Force or attempted repair may result in a fire

or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect

the appliance and to replace any part of the control system

and any gas control which has been under water.

1. STOP! Read the safety information above.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device which

automatically lights the pilot. Do not try to light the pilot

by hand.

5. Remove front panel door.
6. Slide gas control switch to “OFF.”
7. Wait ten (10) minutes to clear out any gas. Then smell

for gas, including near the floor. If you smell gas, STOP!

Follow “B” in the safety information above. If you don’t

smell gas, go to the next step.

8. Slide gas control switch to “ON”.
9. Replace front panel door.
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance will not operate, follow the instructions

“TO TURN OFF GAS TO APPLIANCE” and call your

service technician or gas supplier.

OPERATING INSTRUCTIONS

TO TURN OFF GAS TO APPLIANCE

1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance

if service is to be performed.

3. Remove front panel door.
4. Slide gas control switch to “OFF.”
5. Replace front panel door.

GAS FLOW

GAS VALVE SHOWN IN OFF POSITION

HONEYWELL IP SMART VALVE

OFF

ON

CONTROL

IGNIT

OR

DVC-35IPT INTERMITTENT PILOT LIGHTING INSTRUCTIONS