Introduction

Always consult your local Building Department regarding regulations,

codes or ordinances which apply to the installation of a direct vent wall

furnace.
Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card supplied

with furnace.

3. Installer should show owner how to start and operate furnace and

thermostat.

Warning:

Any change to this furnace or its control can be dangerous. This

is a heating appliance and any panel, door or guard removed for

servicing an appliance must be replaced prior to operating the

appliance.

General Information

This furnace is design certified in accordance with American National

Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards

Association, as a fan type direct vent wall furnace to be installed according

to these instructions.
Any alteration of the original design, installed other than as shown in

these instructions or use with a type of gas not shown on the rating plate

is the responsibility of the person and company making the change.
Important

All correspondence should refer to complete Model No., Serial No. and

type of gas.
Notice: During initial firing of this unit, its paint will bake out and smoke

will occur. To prevent triggering of smoke alarms, ventilate the room in

which the unit is installed.
Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other combustible

material other than wood flooring the appliance shall be installed on a metal

or wood panel extending the full width and depth of the appliance.
The base referred to above does not mean the fire-proof base as used on

wood stoves. The protection is for rugs that are extremely thick and light

colored tile.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed so that

all burners and burner ignition devices are located not less than 18” above

the floor.
Such equipment shall be located, or protected, so it is not subject to physical

damage by a moving vehicle.
Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or

accessories and repair and servicing of equipment shall be performed

only by a qualified agency. The term “qualified agency” means any

individual, firm, corporation or company which either in person or through

a representative is engaged in and is responsible for (a) the installation

or replacement of gas piping or (b) the connection, installation, repair or

servicing of equipment, who is experienced in such work, familiar with

all precautions required and has complied with all the requirements of the

authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed

plumber or gas fitter in the Commonwealth of Massachusetts.

The installation must conform with local codes or, in the absence of local

codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural

Gas and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 West

42nd St., New York, N.Y. 10036.
High Altitudes

For altitudes/elevations above 2,000 feet, input ratings should be reduced

at the rate of 4 percent for each 1,000 feet above sea level. For Canadian

high altitude applications, this appliance is suitable for installation at

elevations between 0 feet and 4,500 feet without change.
Piezo Pilot Ignitor Instructions

Depressing the red button completely causes a spark to occur at the pilot. This

is a substitute for a match which requires opening the pilot hole cover.
To light the pilot, it is important that the electrode be 1/8” from the

thermocouple. The spark must occur at the point the burner flame hits the

thermocouple. The end of the electrode will be red hot with the pilot on.
On a new installation with air in the gas line, it is suggested that a match

be used. The match will light the pilot faster than the piezo under this

condition.

Model

DVC-35T

DVC-35IPT

Input BTU/HR

35,000

35,000

Height

72 1/2”

72 1/2”

Width

14 1/8”

14 1/8”

Depth

10 3/8”

10 3/8”

Gas Inlet

1/2” Pipe

1/2” Pipe

CFM

275

275

Accessories
SOR-1

Register, Side Outlet

SOK-1

Side Outlet Kit, 10” (25.4cm) Boot Assembly with Register

*DV-822

Vinyl Siding Vent Kit

* DV-822, Vinyl siding vent kit, adds 3” to wall depth. You must include the three (3) additional inches for TOTAL wall depth when ordering a

vent kit.