Important safety information vent kit information, This is a heating appliance – Empire Products DVC-35T-1 User Manual

Page 3

Advertising
background image

13119-6-0107

Page 3

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.

Due to high temperatures the appliance should be located

out of traffic and away from furniture and draperies.

• Children and adults should be alerted to the hazards of

high surface temperatures and should stay away to avoid

burns or clothing ignition.

• Young children should be carefully supervised when they

are in the same room as the appliance.

• Clothing or other flammable material should not be placed

on or near the appliance.

• Any safety screen or guard removed for servicing an appli-

ance must be replaced prior to operating the appliance.

• Keep burner and control compartment clean.

• Vent cap hot while furnace is in operation.

• Installation and repair should be done by a QUALIFIED

SERVICE PERSON. The appliance should be inspected

before use and at least annually by a qualified service

person. More frequent cleaning may be required due to

excessive lint from carpeting, bedding materials, etc. It

is imperative that control compartments, burners and

circulating air passageways of the appliance be kept

clean.

• DO NOT put anything around the furnace that will ob-

struct the flow of combustion and ventilation air.

• DO keep the appliance area clear and free from combus-

tible material, gasoline and other flammable vapors and

liquids.

• DO examine venting system periodically and replace

damaged parts.

• DO make a periodic visual check of pilot and burners.

Clean and replace damaged parts.

• CAUTION: Pilot hole cover must be kept tightly closed

during operation.

• DO NOT use this heater if any part has been under water.

Immediately call a qualified service technician to inspect

the heater and to replace any part of the control system

and any gas control which has been under water.

• IMPORTANT: This furnace has a washable permanent

type filter which should be cleaned at least once per

year before the heating season. For dirty or high use

areas more frequent cleaning is required.

Attention: The DVC-35T and DVC-35IPT direct vent wall furnaces are provided with vent kit, DV4T-59-1 for wall depths of 5” to

9”. For wall depths greater than 9”, refer to Accessories, Page 6. Listed below are the vent kits.
Attention: The minimum wall depth for installation of a DVC-35T and DVC-35IPT MUST BE 5”. If the wall depth is less than 5”

you can order DV-822, refer to Accessories, Page 6 or refer to Figure 10 and Figure 11 with accompanying text, Page 11.

Vent Kits

No. Part

DV4T-59-1 DV4T-812-1 DV4T-1219-1

1

Outlet Tube - Inner

13057

13057

13058

2

Gasket - Outer Collar

M-177

M-177

M-177

3

Outlet Tube - Inner

13104

13104

13105

4

Inlet Tube - Inner

13062

13062

13063

5

Gasket - Inlet Collar

M-178

M-178

M-178

6

Inlet Tube - Inner

13106

13106

13107

7

Inlet Tube - Outer

13064

13065

13066

8

Outlet Tube - Outer

13059

13060

13061

9

Vent Cap

13053

13053

13053

Hardware Kit

13078

13078

13078

IMPORTANT SAFETY INFORMATION