Chapter 4 serial ports, Accessing serial buffers – Remote Processing RPC-52 User Manual

Page 13

Advertising
background image

CHAPTER 4

SERIAL PORTS

Page 11

Figure 4-3 Data packet

> 22M B1

The pr otocol starts w ith the < cr> charac ter. This
character synchronizes all units and alerts them that the
next few characters coming down are address and data.
In this case, "> 22" is the units address. "M " is the
comm and and " B1" is the ch ecksum . T he comm and is
terminated with a < cr> character.

A response depends upon the nature of the command.
Suppose command M means "return a digital I/O port
status". The R PC-52 could read the port and r espond
with AA 2< cr> . T he first A is an acknow ledge, that is
no errors w ere detected in the message. The data, A2,
can be broken d own as follows:

Bit/line

7 6 5 4 3 2 1 0

Status

1 0 1 0 0 0 1 0 = A2

Lines 1, 5 and 7 are high while the others are low.

ACCESSING SERIAL BUFFERS

You can access C OM0 and COM 1 buffers in three w ays:

1.

INP UT sta tement. This re moves a ll charac ters in
the buffer up to the term inator cha racter and puts
them into a variable.

When using the INPUT statement, program
execution is susp ended until a < cr> (Enter key) is
received. W hether this is a problem depends on
your particular application.

INPUT strips bit 7. This means ASCII characters
from 0 to 127 are rec eived. The IN PUT statement
can return a maxim um string length of about 150
character s.

2.

GET function. Char acters ar e rem oved one at a
time as a numerical value. A 0 is returned when the
buffer is e mpty. Use the C OM function to
determ ine if the buffer is empty or if a 0 is a data
value.

If you don' t read the b uffer an d the buffer fills, all
subsequent characters are discarded. GET m ay be

u s ed a ny w h er e in th e pr o g ra m .

3.

COM$(n) retrieves all characters in the buffer,
including other control codes (except CR).

A C C E SS I NG C O M 0 AN D C O M 1

The port INP UT and GE T functions retrieve data using
the UIn c omm and. UI0 r outes inputs to C OM 0 while
UI1 routes inputs to the COM1 port. PRINT outputs are
set by the U On com mand. UO0 p rints out C OM 0 while
UO1 outputs COM 1.

The following show how UIn and U On work.

100

UI0

Set to COM0

110

INPUT A

Get data from COM0 port

520

UI1

Switch to COM1 port

530

INPUT B

Get data from COM1 port

800

UO0

P r in t t o C O M 0

810

P R I NT " T e m pe r at ur e : " , T

900

UO1

P r in t t o C O M 1

910

P R I N T " Se t p r e ss u re a t: " , C A

Power up default is set to COM0. UIn has no effect
upon COM $(n) function.

Advertising