0 solution tank – Sandia 12-Gallon, 1200 PSI Hard Surface Extractor User Manual

Page 11

Advertising
background image

(30) 1200 PSI Hard Surface Extractor

1200 PSI Hard Surface Extractor (11)

4.1 Water and Chemical Dilution – Auto Fill Continued

How to Change the Metering Tip
• Remove the chemical feed hose from the barb on the side of the proportioning valve.
• Unscrew and remove the old tip.
• Screw in the proper tip for your chemical tip and place the hose back on the barb.
Metering Tip Kit
The Metering Tip Kit contains 14 different colored metering tips, allowing dilution rates

from 11:1 up to 427:1. Refer to the chart below to select the tip that meets the dilution

rate for your chemical application.
• For example, if you require 1-1/2 ounces of chemical per gallon of water, change to

the red metering tip with the dilution rate of 85:1.

• The dilution rates are based on chemicals with water-like viscosity. Thicker (more

viscous) chemicals will dilute at a different rate.

• DO NOT use powdered chemicals in the machine. Use of powdered chemicals will

void your warranty.

• Contact your distributor if you have questions about your chemical.
Metering Tip Chart

Tip Color

Chemical Dilution Rates

Oz. / Gal.

Ratio

Tan

0.30

427:1

Orange

0.40

320:1

Turquoise

0.50

256:1

Pink

0.75

170:1

Light Blue

1.00

128:1

Brown

1.12

114:1

Red

1.50

85:1

White

1.75

73:1

Green

2.00

64:1

Blue

2.50

51:1

Yellow

3.75

34:1

Black

5.00

26:1

Purple

8.50

15:1

Gray

11.50

11:1

No Tip

16.25

8:1

10.0 Solution Tank

Schematic Drawing

Advertising