Sandia 12-Gallon, 1200 PSI Hard Surface Extractor User Manual

Page 17

Advertising
background image

(24) 1200 PSI Hard Surface Extractor

1200 PSI Hard Surface Extractor (17)

4.7 Switch Panel

Vacuum 1 – Power from

Cord 1

When the switch is turned to the ON

position, power is supplied to the

vacuum motor (3-Stage Vacuum).

Vacuum 2 – Power from

Cord 1

When the switch is turned to the ON

position, power is supplied to the

vacuum motor (2-Stage Vacuum).

Solution Pump Switch –

Power from Cord 2

When the switch is turned to the

ON position, power is supplied

to the solution pump motor

(Extracting Only). DO NOT

turn this switch ON.

Waste Pump Switch – Power from

Cord 2

When switch is turned to the ON position, waste

pump operation is controlled by the float switch

in the recovery tank. Pump will remain OFF until

water level rises to the point at which the float

switch will turn the waste pump ON. DO NOT

turn waste pump switch ON unless a hose is

connect to the pump-out outlet port.

6.10 Clean Pump Inlet Filter Continued

6.11 Flush Chemical System

Chemical build-up in the chemical system can prevent the system from drawing

chemical.
• Rinse the chemical system with fresh water (for heavy chemical build-up, a mild acid

can be added to the rinse water).

• Remove the chemical feed hose from the solution tank and place the end of the

chemical feed hose into water or mild acid solution.

• Connect the auto-fill water supply hose to the water inlet (male quick disconnect) on

the front of the machine.

• Connect the other end of the hose to a water faucet and turn ON the water. Let the

water flow into the tank until you are sure the rinse solution has been drawn through

the proportioner and mixed with the incoming water. The metering tip can be removed

from the proportioner to speed up the process.

• Once the rinse solution has been drawn through the proportioner, turn OFF the water

faucet and disconnect the auto-fill water supply hose.

• Plug in Cord 1 (left side), connect the short 4-foot vacuum hose to the vacuum barb,

turn on one or both vacuums and use the short vacuum hose to remove the water from

the solution tank.

• When the solution tank has been emptied, turn OFF the vacuums and unplug the

power cord.

• Place a bucket under the dump valve and open the dump valve to drain the water from

the recovery tank.

• Close the dump valve and dispose of the water.

1/4” Acorn Strainer
Part No. 10-0845

Pump Inlet Hose

Advertising