All installations and services must be performed by qualified service personnel.

37

IF SYSTEM IS IN LOCKOUT,

THE MODULE WILL RESET

ITSELF AFTER 60 MINUTES

OR MAY BE MANUALLY

RESET BY INTERRUPTING

THE POWER TO THE FURNACE

AT THE DISCONNECT OR

INTERRUPTING THE CALL FOR

HEAT AT THE THERMOSTAT.

IF THIS DOES NOT RESTART

THE SYSTEM, REFER TO THE

TROUBLESHOOTING SECTION

OF THIS MANUAL.

AFTER THE DELAY-TO-FAN-OFF

PERIOD ENDS, THE CIRCULATING

AIR FAN AND (OPTIONAL) ELECTRONIC

AIR CLEANER ARE DE-ENERGIZED.

AFTER DELAY-TO-FAN-ON PERIOD

ENDS (45 SECONDS), CIRCULATING

AIR FAN IS ENERGIZED AT LOW

FIRE HEATING SPEED OR HIGH

FIRE IF W2 IS ENERGIZED. THE

(OPTIONAL) ELECTRONIC AIR

CLEANER AND HUMIDIFIER

ARE ENERGIZED.

IF THERMOSTAT

W2 CONTACTS

ARE CLOSED

OTHERWISE

CALL

FOR

HIGH

FIRE

NO CALL

FOR

HIGH FIRE

THERMOSTAT CLOSES W2

CALLING FOR HIGH FIRE

HEATING.

GAS VALVE, INDUCER AND

AIR FAN ARE ENERGIZED

TO HIGH FIRE SETTINGS

WHEN THERMOSTAT W1 IS SATISFIED,

CONTACTS OPEN AND THE GAS

VALVE IS DE-ENERGIZED. AFTER

PROOF OF FLAME LOSS, INDUCER

STARTS 5 SECOND POST PURGE

AND (OPTIONAL) HUMIDIFIER IS

DE-ENERGIZED. THE DELAY-TO-

FAN-OFF PERIOD BEGINS (120 SECONDS)

WHEN THERMOSTAT HAS

SATISFIED W2, CONTACTS

OPEN AND THE GAS VALVE

AND AIR FAN HIGH FIRE

SETTINGS ARE DE-ENERGIZED

AFTER 30 SECOND DELAY.