All installations and services must be performed by qualified service personnel.

52

CHECK CONNECTIONS

TO GAS VALVE. IF OK,

REPLACE GAS VALVE.

IS THE VARIABLE

SPEED AIR FAN

OPERATING?

DOES BLOWER

SPIN FREELY?

CONFIRM IF EITHER

BLOWER WHEEL

IS RUBBING AGAINST
HOUSING OR MOTOR

SHAFT IS SPINNING

FREELY AND REPAIR

OR REPLACE AS

NECESSARY

DOES SYSTEM RUN

UNTIL THERMOSTAT

IS SATISFIED?

CHECK ALL WIRING FOR

LOOSE CONNECTIONS.

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

REFERENCE ECM

OPERATION MANUAL

IS THERE 24 VOLTS

ACROSS "MVH" AND

"MV COM" ON

50V51-843 CONTROL?

REPLACE THE

50V51-843 CONTROL.

IS LED LIGHT

ON 50V51-843

CONTROL FLASHING?

REFERENCE LED

CHART ON PG. 48
OF THIS MANUAL.