Thermo Pride Gas/Propane Furnace Premiere Series 2-Stage CHX3 User Manual

Page 7

Advertising
background image

All installations and services must be performed by qualified service personnel.

1

II. FURNACE SPECIFICATIONS

CHX3 SERIES

MODEL NO.

CHX3-75

CHX3-100

CHX3-125

BTU/HR INPUT (High fire/ Low fire)

75,000 / 52,000

100,000 / 70,000 125,000 / 87,500

BTU/HR OUTPUT (High fire/ Low fire)

71,000 / 49,000

95,000 / 66,000

115,000 / 82,000

HEIGHT OF CASING

44-1/4”

44-1/4”

44-1/4”

WIDTH OF CASING

17”

21”

24”

DEPTH OF CASING

27-1/2”

27-1/2”

27-1/2”

WARM AIR OUTLET

15 x 18

19 x 18

22 x 18

RETURN AIR INLET

25 x 16

25 x 16

25 x 16

DIA. OF FLUE

2”

3”

3”

DIA. OF COMBUSTION
AIR INTAKE

2”

3”

3”

CFM from .2” & .5” w.c.
EXTERNAL STATIC PRESSURE

COOLING

COOLING

COOLING

@COOLING TAP A

1000

1200

1400

@COOLING TAP B

800

1000

1200

@COOLING TAP C

1200

1400

1600

@COOLING TAP D

1400

1600

2000

HEATING

HEATING

HEATING

@HEATING TAP A (High fire/Low fire)

931 / 760

1243 / 1015

1556 / 1270

TEMPERATURE RISE

70 / 60

70 / 60

70 / 60

BLOWER MOTOR HP

.5

.75

1

POWER CHOKES

-

2.65 Mh

2.1 Mh

LARGEST RECOMMEDED
AIR CONDITIONER

3.5 Ton

4 Ton

5 Ton

SIZE OF FILTERS

24-3/4” x 15-3/4” 24-3/4” x 15-3/4” 24-3/4” x 19-3/4”

NOTES:
1. BTU output based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is

required.