Thermo Pride Spirit Gas TG9S Single Stage PSC 95.5% User Manual

Page 13

Advertising
background image

1083287-UIM-A-0114

Johnson Controls Unitary Products

13

For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available on-line at www.upgnet.com in
the Product Catalog Section.

FIGURE 18: Thermostat Chart - Single Stage AC with Single Stage PSC Furnaces

Single Stage Air Conditioner – Single Stage Furnace

HM1

Humidistat

Y

Full Stage Compressor

G

Fan

*PP11C70224

THERMOSTAT

RH

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

W

Full Stage Heat

Clipping Jumper W914 for

electric heat on thermostat

is not necessary

24VAC Humidifier Relay

(Optional)

C

24 – Volt Common

Y

Compressor Contactor

SINGLE STAGE

AIR

CONDITIONER

G8C

L(Y/M)8S

G*9F

G*(8/9)S

ID MODELS

(G/T)GLS

(G, T)G(8/9)S

LF8

GF(8/9)

C

24 – Volt Common

R

24 – Volt Hot

W

Full Stage Heat

SINGLE STAGE

FURNACE

G

Fan

SINGLE STAGE

FURNACE

Y/Y2

Full StageCompressor

Advertising