Single stage heat pump – single stage furnace, Electronic air cleaner connection – Thermo Pride Spirit Gas TG9S Single Stage PSC 95.5% User Manual

Page 14

Advertising
background image

1083287-UIM-A-0114

14

Johnson Controls Unitary Products

ACCESSORY CONNECTIONS

The furnace control will allow power-switching control of various acces-
sories.

ELECTRONIC AIR CLEANER CONNECTION

Two 1/4” (6.4 mm) spade terminals (EAC and NEUTRAL) for electronic
air cleaner connections are located on the control board. The terminals
provide 115 VAC (1.0 amp maximum) during circulating blower opera-
tion.

FIGURE 19: Thermostat Chart - Single Stage HP with Single Stage PSC Furnaces

Single Stage Heat Pump – Single Stage Furnace

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

O

Reversing Valve

Energized in Cool

L

Malfunction Light

G

Fan

*DP32H70124

THERMOSTAT

W1

Second Stage Aux. Heat

E

Emergency Heat

W2

Third Stage Heat

N/A

*BP21H50124

*BN21H00124
*DP21H40124

*DN21H00124

THERMOSTAT

N/A

*DN22U00124

THERMOSTAT

E*B*

E*ZD

E*R*

OD MODELS

*HGD

HP*

*RHS

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

W1/66(out)

Heat

Y

Compressor

DEMAND DEFROST

CONTROL

X/L

Malfunction Light

W

Auxiliary Heat

SINGLE STAGE

HEAT P UMP

24VAC Humidifier Relay

(Optional)

External Humidistat

(Optional)

Open on Humidity Rise

Y2

Second Stage Compressor

Step 9 of Thermostat

Installer / Configuration

Menu must be set to

Pump OFF

Step 1 of Thermostat

Installer / Configuration

Menu must be set to

Heat Pump 1

G8C

L(Y/M)8S

G*9F

G*(8/9)S

ID MODELS

(G/T)GLS

(G,T)G(8/9)S

LF8

GF(8/9)

C

24 – Volt Common

R

24 – Volt Hot

W

Full Stage Heat

SINGLE STAGE

FURNACE

G

Fan

SINGLE STAGE

FURNACE

Y/Y2

Full Stage Compressor

Advertising