Elektra Beckum Cool 401 User Manual

Page 23

Advertising
background image

23

11.02

5.2.2

Acknowledgement of
failures

Fig. 21: Acknowledgement of

failures

5.2.3

Function:

Cause

No function

5.2.4

Water in compressed
air system

Cause

5.2.4.1 Condensate is not

drained properly

5.2.4.2 electronic regulated

condensate drain

5.2.4.2.1 Faulty condensate

draining

5.2.4.2.2 Solenoid valve de-

fective

Part 5

Maintenance

Remedy

- Check and establish power supply if necessary
- If the power supply is ok, call for service or send CA-

dryer to the manufacturer.

Remedy

- check condensate separator behind the compressor.
- possibly install automatic drain

- no sufficient drainage of the condensate separator

behind the compressor, extend condensate draining
time.

Clean solenoid valve

Replace solenoid valve

1. For acknowledgement operate

data selector key ( ) for 5
seconds.

2. Operate data selector key ( )

once more until P02 appears .

3. Acknowledgement of failure

through condensate drain
key ( )

4. For returning into display mode

press data selector key ( )
for 5 seconds.