5.2.6

High differential
pressure at CA-side:

Cause

5.2.6.1 Compressed air volume

flow too high

5.2.6.2 Working pressure too

low

5.2.6.3 Icing of CA-dryer

Remedy

Check whether CA-dryer´s capacity is properly selected,
increase CA-dryer´s capacity

Increase operating pressure, check whether CA-dryer´s
capacity is properly selected

Characteristics:

- differential pressure at com-
pressed air side increases
- volume flow decreases

Disconnect unit and maintain compressed air flow. After
approx. half an hour, the differential pressure will return
to normal value. Restart the unit. If the heat exchanger
ices up again call for service.