11.02

2.1

Transportation

2.2

Requirements on
the place of in-
stallation

2.3

Installation
(mount ing)

Fig. 1: Installation of

CA-dryer

Part 2

Installation

Transportation has to be carried out in the normal oper-
ating position of the CA-dryer.
For a short time an inclined position of 45 ° is allowed.

At the site of installation, the CA-dryer can be installed
without anchorage or special foundation at the location
desired.
The CA-dryer is provided for an ambient temperature of
25 °C.

Attention!
To avoid corrosion at components of the CA-dryer the
compressed and ambient air must be free of aggressive
parts.
The CA-dryers are provided for inside mounting.
Deviating conditions require the consultation of the manu-
facturer.

To prevent the condensate from freezing the room tem-
perature must not drop below +2 °C.

Attention!
At different ambient conditions pay attention to the lay-
out data!

The CA-dryer must be installed that accessibility to the
front panel is ensured. Furthermore leave space for serv-
ice purpose on both sides of the CA-dryer (fig. 1).

Wall mounting is possible with all types.

!

!