ETA Systems FC01-LQ User Manual

Page 41

Advertising
background image

Flow Meter FC01-LQ

Flow Meter FC01-LQ

Configuration

35

Configuration

35

5.10 Analogue output - flow rate (menu option: ANA OUT FLOW)

This menu option allows adjustment of the flow rate analogue output specifically to the
requirement of the entire system.

Options are:

OFFSET =

0%/20% FS (0/4 … 20 mA, 0/1 … 5 V, 0/2 … 10 V)

ZERO =

(initial value 0(20) % corresponds to a flow rate of _ [m/s] [%] [FPS])

FS =

(final value 100% corresponds to a flow rate of _ [m/s] [%] [FPS])

When entering the initial or final value, the user should observe a reasonable resolution!

With a flow volume/time unit selected in menu DISPLAY SELECT and when setting the initial and
end values, the pertinent flow volumes will also be indicated.

5.11 Analogue output - medium temperature

(menu option: ANA OUT TEMP.)

In conformance with the configuration “Flow rate analogue output” it is possible to adjust the
medium temperature analogue output to the requirements of the entire system.

Options are:

OFFSET =

0%/20% FS (0/4 … 20 mA, 0/1 … 5 V, 0/2 … 10 V)

• ZERO

=

(initial value 0(20) % corresponds to a medium temperature of … [°C] [°F] [K])

• FS

=

(final value 100% corresponds to a medium temperature of … [°C] [°F] [K])

When entering the initial or final value, the user should observe a reasonable resolution!

5.12 Quitting the configuration menu

Upon configuration of the analogue outputs, the menu may be quitted or re-set to the start
(SENSOR SELECT).

To quit the configuration menu, the controller will check the data entered for plausibility.

“CONFIG. OK!” is indicated when the data are found correct. The menu may than be quitted by

pressing MODE.
Errors found during the plausibility check are indicated in the following sequence of priority.

Priority of entry errors in the CONFIGURATION menu:

ERR. A-OUT FLOW

OUT OF RANGE

(flow analogue output outside measuring range)

ERR. A-OUT FLOW

ZERO

≥ FS

( initial value

≥ final value with flow analogue output)

ERR. A-OUT TEMP.

OUT OF RANGE

(temperature analogue output outside measuring range)

• ERR. A-OUT TEMP.

ZERO

≥ FS

(initial value

≥ final value with temperature analogue output)

M

5.10 Analogue output - flow rate (menu option: ANA OUT FLOW)

This menu option allows adjustment of the flow rate analogue output specifically to the
requirement of the entire system.

Options are:

OFFSET =

0%/20% FS (0/4 … 20 mA, 0/1 … 5 V, 0/2 … 10 V)

ZERO =

(initial value 0(20) % corresponds to a flow rate of _ [m/s] [%] [FPS])

FS =

(final value 100% corresponds to a flow rate of _ [m/s] [%] [FPS])

When entering the initial or final value, the user should observe a reasonable resolution!

With a flow volume/time unit selected in menu DISPLAY SELECT and when setting the initial and
end values, the pertinent flow volumes will also be indicated.

5.11 Analogue output - medium temperature

(menu option: ANA OUT TEMP.)

In conformance with the configuration “Flow rate analogue output” it is possible to adjust the
medium temperature analogue output to the requirements of the entire system.

Options are:

OFFSET =

0%/20% FS (0/4 … 20 mA, 0/1 … 5 V, 0/2 … 10 V)

• ZERO

=

(initial value 0(20) % corresponds to a medium temperature of … [°C] [°F] [K])

• FS

=

(final value 100% corresponds to a medium temperature of … [°C] [°F] [K])

When entering the initial or final value, the user should observe a reasonable resolution!

5.12 Quitting the configuration menu

Upon configuration of the analogue outputs, the menu may be quitted or re-set to the start
(SENSOR SELECT).

To quit the configuration menu, the controller will check the data entered for plausibility.

“CONFIG. OK!” is indicated when the data are found correct. The menu may than be quitted by

pressing MODE.
Errors found during the plausibility check are indicated in the following sequence of priority.

Priority of entry errors in the CONFIGURATION menu:

ERR. A-OUT FLOW

OUT OF RANGE

(flow analogue output outside measuring range)

ERR. A-OUT FLOW

ZERO

≥ FS

( initial value

≥ final value with flow analogue output)

ERR. A-OUT TEMP.

OUT OF RANGE

(temperature analogue output outside measuring range)

• ERR. A-OUT TEMP.

ZERO

≥ FS

(initial value

≥ final value with temperature analogue output)

M

Advertising