Flow Meter FC01-LQ

Flow Meter FC01-LQ

54

Technical data

54

Technical data

Inner pipe diamater

Measuring range

Display range

D in mm

in m

3

/h

in m

3

/h

50

21

28

80

55

70

100

85

110

150

190

250

200

340

450

250

530

700

350

1040

1380

500

2120

2830

Setting range for internal pipe diameter:

50.0 mm … 999.9 mm

Measuring range:

0.05 … 3 m/s

Display range:

0 … 4 m/s

Response delay:

2.5 s

Repeatability:

1% MW **

(5% MBE to 100% MBE)

Accuracy:

±1% MBE * at 2 m/s

see failure ddiagram)

Failure diagram for water

Inner pipe diamater

Measuring range

Display range

D in mm

in m

3

/h

in m

3

/h

50

21

28

80

55

70

100

85

110

150

190

250

200

340

450

250

530

700

350

1040

1380

500

2120

2830

Setting range for internal pipe diameter:

50.0 mm … 999.9 mm

Measuring range:

0.05 … 3 m/s

Display range:

0 … 4 m/s

Response delay:

2.5 s

Repeatability:

1% MW **

(5% MBE to 100% MBE)

Accuracy:

±1% MBE * at 2 m/s

see failure ddiagram)

Failure diagram for water

8.00

6.00

4.00

2.00

0.00

-2.00

-4.00

-6.00

-8.00

v (m/s)

f (% of upper range value)

+f max

-f max

calibration point at 2 m/s:

±1% of upper range value

0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00

0

8.00

6.00

4.00

2.00

0.00

-2.00

-4.00

-6.00

-8.00

v (m/s)

f (% of upper range value)

+f max

-f max

calibration point at 2 m/s:

±1% of upper range value

0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00

0