EverFocus EMV200 User Manual

Page 39

Advertising
background image

32

Output Type:

Timeout: Alarm output lasts for the set time duration.

Permanent: Alarm will be continuously active until user presses the “Enter” key or resets the alarm remotely.

Transparent: Alarm output remains active until event ends.

Trans+Timeout: Alarm output continues until event ends, then continues for the set time duration.

Timeout Duration: Time duration selectable from 1 to 150 seconds.

Click

button to return to the previous level of menu.

Power Loss:

Figure 4-16 Alarm – Event – Power Loss

Email Notify: Check box to enable email notification when power has been restored. Email operation requires
that valid email settings have been entered in the Network Setting/Email setup screen.

Network Alarm: Check box to send out a network alarm to client PC when power has been restored. (requires
PowerCon software and setting up Alarm Server in Network Setup menu)

NOTE: As alarms and emails cannot be transmitted without power, the log entry is made when power is restored,
and any notifications cannot be made until that time.

Click

button to return to the previous level of menu.