Elmo SERVO AMPLIFIER DBP SERIES User Manual

Page 72

Advertising
background image

71

DBP - Rev 6/93

AC

AC

AC

+Vs

DC power common

Control common

Heatsink

Fuse

Fuse

Fuse

AC

AC

AC

+Vs

DC power common

Control common

Heatsink

To additional

DBPs

CONNECTING MORE THAN ONE DBP

DIRECT CONNECTION TO

THE THREE PHASE MAINS

NOTE: DC POWER TERMINALS ARE

CONNECTED IF SINGLE PHASE

IS USED OR IF SHUNT CURRENT

HAS TO BE INCREASED

DBP

DBP

O option

O option

A. External fuses are needed

for 3U size only

Advertising