8. Applying power - Adjustments

Important remarks:

A. If all the previous steps were accomplished you may now disconnect the motor

leads, turn the power on and continue with the following adjustments.

Step 1 - Applying Power

Apply power and check for LED Vs of the DCB that should be "ON", indicating

that the system supplies are present. The display should read: "F-OK". If you

get another message, refer to the following table to find the cause of the

problem. Turn the power off, clear the cause of the problem and re-power the

unit.

Event

Display

Display

after

Recurring

DIP switch 1 - ON

BAUD

OK

Load is under cont. current limit

CLIM

C-OK

Battery Low

BATT

B-OK

Abort condition (hardware only)

ABRT

A-OK

Amplifier's power stage disabled

*

AMPD

H-OK

-15V out of limits

-15V

F-OK

Under or Over Voltage

VOLT

F-OK

+15V out of limits

+15V

F-OK

Over Temperature

TEMP

F-OK

Commutation problem

CMMT

F-OK

Short condition at the power outputs

SHRT

F-OK

*

The AMPD message appears in two cases:

1. When MO (Motor Off) command is given.

2. Position error exceeds the allowed value.