Amprobe ACD-30P Clamp-On-Power-Meters User Manual

Page 13

Advertising
background image

12

EMC: en 61326-1 This product complies with requirements of the following

european Community Directives: 89/336/eeC (electromagnetic Compatibility) and
73/23/eeC (low Voltage) as amended by 93/68/eeC (Ce Marking). however, electrical
noise or intense electromagnetic fields in the vicinity of the equipment may disturb the
measurement circuit. Measuring instruments will also respond to unwanted signals that
may be present within the measurement circuit. Users should exercise care and take
appropriate precautions to avoid misleading results when making measurements in the
presence of electronic interference.

Electrical (23 °C ± 5 °C) < 75% Rh

AC Voltage

Voltage

Range

Accuracy

600.0V

50hz to 60hz

± (0.5% rdg + 5d)

45 to 50hz, 60 to 500hz

± (1.5% rdg + 5d)

500hz to 3.1khz

± (2.5% rdg + 5d)

CMRR :

> 60 dB @ DC to 60 hz, Rs = 1 kΩ

input impedance:

2 MΩ, 30 pf nominal

Crest factor:

< 2.3 : 1 at full scale; < 4.6 : 1 at half scale

ACV AutoVA

TM

Threshold:

30VAC (40 to 500 hz) nominal

DC Voltage

Range:

600.0 V

Accuracy:

± (0.5% rdg + 5d)

nMRR :

> 50 dB @ 50/60 hz

CMRR :

>120 dB @ DC, 50/60 hz, Rs = 1 kΩ

input impedance:

2 MΩ, 30 pf nominal

DCV AutoVA

TM

Threshold:

2.4VDC nominal

PEAk-rms HoLD (ACA & ACV only)
Response: 65ms to 90% rdg

ohms

Range:

000.0 to 999.9 Ω

Accuracy:

± (1.0% rdg + 6d)

open Circuit Voltage :

0.4VDC typical

Audible Continuity tester
Audible threshold: between 10Ω and 300Ω.
Response time: 250μs

ACA Current (Clamp-on)

Advertising