EMC QLogic User Manual

Page 19

Advertising
background image

2

Installing an HBA

2-7

Installing and Configuring the HBA Driver

7. Enter a value for the loop ID and press

ENTER

.

8. Press

ESC

to return to the Configuration Settings menu.

9. Press

ESC

to return to the Fast!UTIL Options menu.

10. When prompted to save changes made to the current adapter,

select Save Changes and press

ENTER

.

11. If there are more adapters to configure, choose Select Host

Adapter

, and repeat steps 3 through 11 for each adapter.

12. Press

ESC

to exit Fast!UTIL.

13. Reboot the host.

14. Repeat this procedure on all nodes in the cluster connected to the

CX200-Series array.

15. While you are in the BIOS, you can verify that the topology is set

correctly for direct connect (FC-AL). Follow the instructions
under Setting the Topology for QLA22xx/23xx and Windows on
page 2-13.

CAUTION

!

Future use of the firmware NVRAM file to apply settings will
overwrite and possibly invalidate the changes made above. If you
will later update using a firmware NVRAM file, be sure it is listed
and supports this CX200-Series direct-connect cluster
configuration.

To restore EMC default HBA settings, either reload the approved EMC
NVRAM file, or return to step 5 and ensure that Adapter Hard Loop ID is set
to Disabled.

QLogic_Windows.book Page 7 Thursday, March 10, 2005 10:31 AM